We depend on sturdy technical force and continually create sophisticated technology to meet the demand of Super Lowest Price Aluminum Liquid Nitrogen Tank Square Racks Storage Biological Liquid Nitrogen Container, Ka anyị na-aga n'ihu, anyị na-ejide anya na ngwaahịa anyị na-agbasawanye ma na-eme imeziwanye ụlọ ọrụ anyị.
Anyị na-adabere na ike nka siri ike ma na-emepụta teknụzụ ọkaibe iji gboo ihe achọrọHaier Liquid Nitrogen Container na -196 Degree maka IVF, Anyị na-esi ọnwụ na "Quality First, aha mbụ na ahịa mbụ".Anyị na-agba mbọ ịnye ngwa ahịa dị elu yana ezigbo ọrụ mgbe irechara.Ruo ugbu a, ebupụla ngwa ahịa anyị gaa na mba na mpaghara 60 gburugburu ụwa, dịka America, Australia na Europe.Anyị nwere aha dị elu n'ụlọ na ná mba ọzọ.N'ịnọgide na-adịgide adịgide na ụkpụrụ nke "Ebe E Si Nweta, Onye Ahịa na Ogo", anyị na-atụ anya imekọ ihe ọnụ na ndị mmadụ n'akụkụ niile nke ndụ maka uru otu.
Nchịkọta:
Nyochaa: Nnukwu ụlọ nyocha ụlọ nyocha mmiri ikuku nitrogen na-ejikọta uru nke oriri nitrogen dị ala na ikike nchekwa ọkara.Ọ nwere uru nke ịdị arọ dị arọ, obere ọrụ ohere yana nchekwa nchekwa dị elu nke nnukwu ihe nlele.Ọ nwere ike gboo mkpa dị iche iche nke ndị ọkachamara ụlọ nyocha.Modelsdị niile gụnyere shelf ifriizi na igbe friza PC iji hụ na nchekwa nke ihe nlele dị mfe.
Njirimara ngwaahịa:
① Ọdịdị aluminum na-adịgide adịgide;
② Ejiri akwa na igbe vial;
③ Nnukwu ikike, obere mmiri nitrogen oriri;
④ mkpuchi mkpuchi bụ nhọrọ, iji dobe nchekwa nke ihe nlele;
⑤ Usoro nlekota ọkwa ọkwa bụ nhọrọ;
⑥ Roller base bụ nhọrọ;
⑦ CE akwụkwọ ikike;
⑧ Akwụkwọ ikike afọ ise;
Ọchụchọ nlele:
Maka imewe nchekwa ogologo oge, ọ dị mfe iburu ma tinye ihe nlele;
Mpempe akwụkwọ oyi kpọnwụrụ akara na igbe cryo maka ịnweta ngwa ngwa na ịrụ ọrụ nke ọma na nlele achọrọ;
Enwere ike ịkwado ya na ihe nleba anya ọkwa mmiri mmiri, ọkwa ọkwa nleba anya n'ezie, wee nye ụda ọkwa dị ala na mkpu ọkụ;
Nyochaa ọkwa:
Nye ihe nleba anya ọkwa dị elu iji chebe ihe nlere anya na-enweghị ike dochie ya
Mgbe ọkwa mmiri nitrogen dị ala, ga-enye ụda na mkpu ọkụ iji chetara Anyị na-adabere na ike teknụzụ siri ike ma na-emepụta teknụzụ ọkaibe iji gboo ọchịchọ nke Super Lowest Price Aluminom Liquid Nitrogen Tank Square Racks Nchekwa Biological Liquid Nitrogen Container, Dị ka anyị bụ. na-aga n'ihu, anyị na-eleba anya na ngwaahịa anyị na-abawanye ụba ma na-eme ka ụlọ ọrụ anyị dịkwuo mma.
Nnukwu ọnụ ahịa Nitrogen Liquid China Liquid Nitrogen na -196, anyị na-ekwusi ike na "ịdị mma mbụ, aha mbụ na ndị ahịa mbụ".Anyị na-agba mbọ ịnye ngwa ahịa dị elu yana ezigbo ọrụ mgbe irechara.Ruo ugbu a, ebupụla ngwa ahịa anyị gaa na mba na mpaghara 60 gburugburu ụwa, dịka America, Australia na Europe.Anyị nwere aha dị elu n'ụlọ na ná mba ọzọ.N'ịnọgide na-adịgide adịgide na ụkpụrụ nke "Ebe E Si Nweta, Onye Ahịa na Ogo", anyị na-atụ anya imekọ ihe ọnụ na ndị mmadụ n'akụkụ niile nke ndụ maka uru otu.
Nlereanya | YDS-10-125-F | YDS-30-125-F | YDS-35-125-F | YDS-47-127-6Y | YDS-50B-125-F |
Arụmọrụ | |||||
Ike LN2 (L) | 10 | 31.5 | 35.5 | 47 | 50 |
Ibu efu (kg) | 6.3 | 13 | 14.6 | 18.2 | 17.3 |
Mmepe olu (mm) | 125 | 125 | 125 | 127 | 125 |
Dayameta elu (mm) | 300 | 462 | 462 | 508 | 462 |
N'ozuzu Elu (mm) | 625 | 704 | 748 | 718 | 818 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.42 | 0.35 | 0.36 | 0.36 | 0.45 |
Oge Njide Static (ụbọchị) | 24 | 90 | 97 | 130 | 110 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 1 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 82×84 | 82×84 | 82×84 | 105×100 | 82×84 | |
Akụkụ Vial igbe (mm) | 76×76 | 76×76 | 76×76 | 98 | 76×76 | |
Igbe kwa Rack (ea) | 4 | 4 | 5 | 5 | 6 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 100 | 600/700 | 750/875 | 1110/1295 | 900/1050 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | ── | ── | ── | ── | ── |
Akụkụ ihe mgbochi (mm) | ── | ── | ── | ── | ── | |
Akụkụ Vial igbe (mm) | ── | ── | ── | ── | ── | |
Igbe kwa Rack (ea) | ── | ── | ── | ── | ── | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | ── | ── | ── | ── | ── |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | √ | √ | ── | √ |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | ── | √ | √ | √ | √ |
Nlereanya | YDS-65-216-F | YDS-95-216-F | YDS-115-216-F | YDS-145-216-F | YDS-175-216-F |
Arụmọrụ | |||||
Ike LN2 (L) | 65 | 95 | 115 | 145 | 175 |
Ibu efu (kg) | 38.3 | 41.3 | 42.3 | 48.9 | 53.8 |
Mmepe olu (mm) | 216 | 216 | 216 | 216 | 216 |
Dayameta elu (mm) | 681 | 681 | 681 | 681 | 681 |
N'ozuzu Elu (mm) | 712 | 774 | 846 | 946 | 1060 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.78 | 0.97 | 0.94 | 0.96 | 0.95 |
Oge Njide Static (ụbọchị) | 83 | 98 | 122 | 151 | 184 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142×144 | 142×144 | 142 x 144 | 142x144 | 142x144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134 x 134 | 134 x 134 | 134 x 134 | 134×134 | |
Igbe kwa Rack (ea) | 4 | 5 | 6 | 8 | 10 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 2400/2800 | 3000/3500 | 3600/4200 | 4800/5600 | 6000/7000 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142x144 | 142x144 | 142 x 144 | 142x144 | 142×144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134×134 | 134 x 134 | 134 x 134 | 134 x 134 | |
Igbe kwa Rack (ea) | 2 | 2 | 3 | 4 | 5 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 972/1134 | 972/1134 | 1458/1701 | 1944/2268 | 2430/2835 |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | ── | ── | ── | ── |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | √ | √ | √ | √ | √ |