"Ọdịmma 1st, Ime ihe n'eziokwu dị ka ntọala, enyemaka sitere n'obi na uru ọ bụla" bụ echiche anyị, iji mepụta mgbe niile ma na-agbaso ọmarịcha mma maka China Yds-175-216 Cryogenic Liquid Nitrogen Storage Container with Rack, Ezigbo mma bụ isi ihe. ihe na-eme ka ụlọ ọrụ ahụ pụọ na ndị asọmpi ndị ọzọ.Ịhụ bụ ikwere, chọrọ ozi ndị ọzọ?Naanị nnwale na ngwaahịa ya!
"Quality 1st, Ime ihe n'eziokwu dị ka isi, ezi obi enyemaka na otu uru" bụ echiche anyị, iji mepụta anọgide na-achụso ndị kasị mma makaIhe nchekwa Nitrogen China, Akpa Nitrogen Liquid, Ụlọ ọrụ anyị na-agbaso echiche nchịkwa nke "na-edebe ihe ọhụrụ, na-achụso mma".Na ndabere nke na-emesi uru nke ngwaahịa dị ugbu a, anyị na-anọgide na-ewusi ike na ịgbatị mmepụta ngwaahịa.Ụlọ ọrụ anyị na-ekwusi ike na ihe ọhụrụ iji kwalite mmepe mmepe nke ụlọ ọrụ, ma mee ka anyị bụrụ ndị na-ebubata ihe dị elu nke ụlọ.
Nchịkọta:
Nyochaa: Nnukwu ụlọ nyocha ụlọ nyocha mmiri ikuku nitrogen na-ejikọta uru nke oriri nitrogen dị ala na ikike nchekwa ọkara.Ọ nwere uru nke ịdị arọ dị arọ, obere ọrụ ohere yana nchekwa nchekwa dị elu nke nnukwu ihe nlele.Ọ nwere ike gboo mkpa dị iche iche nke ndị ọkachamara ụlọ nyocha.Modelsdị niile gụnyere shelf ifriizi na igbe friza PC iji hụ na nchekwa nke ihe nlele dị mfe.
Njirimara ngwaahịa:
① Ọdịdị aluminum na-adịgide adịgide;
② Ejiri akwa na igbe vial;
③ Nnukwu ikike, obere mmiri nitrogen oriri;
④ mkpuchi mkpuchi bụ nhọrọ, iji dobe nchekwa nke ihe atụ;
⑤ Usoro nlekota ọkwa ọkwa bụ nhọrọ;
⑥ Roller base bụ nhọrọ;
⑦ CE akwụkwọ ikike;
⑧ Akwụkwọ ikike afọ ise;
Ọchụchọ nlele:
Maka imewe nchekwa ogologo oge, ọ dị mfe iburu ma tinye ihe nlele;
Mpempe akwụkwọ oyi kpọnwụrụ akara na igbe cryo maka ịnweta ngwa ngwa na ịrụ ọrụ nke ọma na nlele achọrọ;
Enwere ike ịkwado ya na ihe nleba anya ọkwa mmiri mmiri, ọkwa ọkwa nleba anya n'ezie, wee nye ụda ọkwa dị ala na mkpu ọkụ;
Nyochaa ọkwa:
Nye ihe nleba anya ọkwa dị elu iji chebe ihe nlere anya na-enweghị ike dochie ya
Mgbe mmiri mmiri nitrogen larịị bụ ala, ga-enye ụda na ìhè mkpu na-echetara"Quality 1st, Ime ihe n'eziokwu dị ka isi, ezi obi enyemaka na ibe uru" bụ echiche anyị, iji mepụta anọgide na-achụso mma maka Popular Design maka China Yds -175-216 Cryogenic Liquid Nitrogen Storage Container with Rack, Ezigbo mma bụ isi ihe na-eme ka ụlọ ọrụ ahụ pụọ na ndị asọmpi ndị ọzọ.Ịhụ bụ ikwere, chọrọ ozi ndị ọzọ?Naanị nnwale na ngwaahịa ya!
Nhazi ewu ewu makaIhe nchekwa Nitrogen China, Akpa Nitrogen Liquid, Ụlọ ọrụ anyị na-agbaso echiche nchịkwa nke "na-edebe ihe ọhụrụ, na-achụso mma".Na ndabere nke na-emesi uru nke ngwaahịa dị ugbu a, anyị na-anọgide na-ewusi ike na ịgbatị mmepụta ngwaahịa.Ụlọ ọrụ anyị na-ekwusi ike na ihe ọhụrụ iji kwalite mmepe mmepe nke ụlọ ọrụ, ma mee ka anyị bụrụ ndị na-ebubata ihe dị elu nke ụlọ.
Nlereanya | YDS-10-125-F | YDS-30-125-F | YDS-35-125-F | YDS-47-127-6Y | YDS-50B-125-F |
Arụmọrụ | |||||
Ike LN2 (L) | 10 | 31.5 | 35.5 | 47 | 50 |
Ibu efu (kg) | 6.3 | 13 | 14.6 | 18.2 | 17.3 |
Mmepe olu (mm) | 125 | 125 | 125 | 127 | 125 |
Dayameta dị n'èzí (mm) | 300 | 462 | 462 | 508 | 462 |
N'ozuzu Elu (mm) | 625 | 704 | 748 | 718 | 818 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.42 | 0.35 | 0.36 | 0.36 | 0.45 |
Oge Njide Static (ụbọchị) | 24 | 90 | 97 | 130 | 110 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 1 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 82×84 | 82×84 | 82×84 | 105×100 | 82×84 | |
Akụkụ Vial igbe (mm) | 76×76 | 76×76 | 76×76 | 98 | 76×76 | |
Igbe kwa Rack (ea) | 4 | 4 | 5 | 5 | 6 | |
1.2;1.8 & 2 ml Vials (Edede n'ime) | 100 | 600/700 | 750/875 | 1110/1295 | 900/1050 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | ── | ── | ── | ── | ── |
Akụkụ ihe mgbochi (mm) | ── | ── | ── | ── | ── | |
Akụkụ Vial igbe (mm) | ── | ── | ── | ── | ── | |
Igbe kwa Rack (ea) | ── | ── | ── | ── | ── | |
1.2;1.8 & 2 ml Vials (Edede n'ime) | ── | ── | ── | ── | ── |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | √ | √ | ── | √ |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | ── | √ | √ | √ | √ |
Nlereanya | YDS-65-216-F | YDS-95-216-F | YDS-115-216-F | YDS-145-216-F | YDS-175-216-F |
Arụmọrụ | |||||
Ike LN2 (L) | 65 | 95 | 115 | 145 | 175 |
Ibu efu (kg) | 38.3 | 41.3 | 42.3 | 48.9 | 53.8 |
Mmepe olu (mm) | 216 | 216 | 216 | 216 | 216 |
Dayameta dị n'èzí (mm) | 681 | 681 | 681 | 681 | 681 |
N'ozuzu Elu (mm) | 712 | 774 | 846 | 946 | 1060 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.78 | 0.97 | 0.94 | 0.96 | 0.95 |
Oge Njide Static (ụbọchị) | 83 | 98 | 122 | 151 | 184 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142×144 | 142×144 | 142 x 144 | 142x144 | 142x144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134 x 134 | 134 x 134 | 134 x 134 | 134×134 | |
Igbe kwa Rack (ea) | 4 | 5 | 6 | 8 | 10 | |
1.2;1.8 & 2 ml Vials (Edede n'ime) | 2400/2800 | 3000/3500 | 3600/4200 | 4800/5600 | 6000/7000 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142x144 | 142x144 | 142 x 144 | 142x144 | 142×144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134×134 | 134 x 134 | 134 x 134 | 134 x 134 | |
Igbe kwa Rack (ea) | 2 | 2 | 3 | 4 | 5 | |
1.2;1.8 & 2 ml Vials (Edede n'ime) | 972/1134 | 972/1134 | 1458/1701 | 1944/2268 | 2430/2835 |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | ── | ── | ── | ── |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | √ | √ | √ | √ | √ |