N'ịgbaso na tiori nke "ịdịmma, ọrụ, arụmọrụ na uto", ugbu a, anyị enwetala ntụkwasị obi na otuto sitere n'aka onye na-azụ ahịa ụlọ na nke mba ụwa maka Haier Gold Supplier maka Yds-65-216 Durable na Reliable Lab Grade Liquid Nitrogen Dewars maka Bio-Sample Nchekwa. Nkwa, Ọ bụrụ na ị nwere mmasị na ngwaahịa ọ bụla, biko nweere onwe gị ịkpọtụrụ anyị maka ozi ndị ọzọ ma ọ bụ biko zitere anyị email ozugbo, anyị ga-aza gị n'ime awa 24 ma a ga-enye nkọwa kacha mma.
N'ịgbaso na tiori nke "ịdịmma, ọrụ, arụmọrụ na uto", ugbu a, anyị enwetala ntụkwasị obi na otuto sitere n'aka onye na-azụ ahịa ụlọ na nke mba ụwa.Haier Liquid Nitrogen Tank na mmiri mmiri Nitrogen akpa, Ụlọ ọrụ anyị na-ekpuchi mpaghara nke mita 12,000, ma nwee ndị ọrụ 200, n'etiti ndị isi ọrụ nkà na ụzụ 5.Anyị na-pụrụ iche na-emepụta. Anyị ugbu a nwere ọgaranya ahụmahụ na mbupụ.Nnọọ ịkpọtụrụ anyị na a ga-aza ajụjụ gị ozugbo enwere ike.
Nchịkọta:
Nyochaa: Nnukwu ụlọ nyocha ụlọ nyocha mmiri ikuku nitrogen na-ejikọta uru nke oriri nitrogen dị ala na ikike nchekwa ọkara.Ọ nwere uru nke ịdị arọ dị arọ, obere ọrụ ohere yana nchekwa nchekwa dị elu nke nnukwu ihe nlele.Ọ nwere ike gboo mkpa dị iche iche nke ndị ọkachamara ụlọ nyocha.Modelsdị niile gụnyere shelf ifriizi na igbe friza PC iji hụ na nchekwa nke ihe nlele dị mfe.
Njirimara ngwaahịa:
① Ọdịdị aluminum na-adịgide adịgide;
② Ejiri akwa na igbe vial;
③ Nnukwu ikike, obere mmiri nitrogen oriri;
④ mkpuchi mkpuchi bụ nhọrọ, iji dobe nchekwa nke ihe nlele;
⑤ Usoro nlekota ọkwa ọkwa bụ nhọrọ;
⑥ Roller base bụ nhọrọ;
⑦ CE akwụkwọ ikike;
⑧ Akwụkwọ ikike afọ ise;
Ọchụchọ nlele:
Maka imewe nchekwa ogologo oge, ọ dị mfe iburu ma tinye ihe nlele;
Mpempe akwụkwọ oyi kpọnwụrụ akara na igbe cryo maka ịnweta ngwa ngwa na ịrụ ọrụ nke ọma na nlele achọrọ;
Enwere ike ịkwado ya na ihe nleba anya ọkwa mmiri mmiri, ọkwa ọkwa nleba anya n'ezie, wee nye ụda ọkwa dị ala na mkpu ọkụ;
Nyochaa ọkwa:
Nye ihe nleba anya ọkwa dị elu iji chebe ihe nlere anya na-enweghị ike dochie ya
Mgbe mmiri mmiri nitrogen larịị bụ ala, ga-enye ụda na ìhè mkpu na-echetaraAdhering n'ime tiori nke "àgwà, ọrụ, arụmọrụ na uto", ugbu a, anyị enwetala ntụkwasị obi na otuto si n'ụlọ na mba shopper maka Haier Gold Supplier maka Yds- 65-216 Na-adịgide adịgide na Reliable Lab Grade Liquid Nitrogen Dewars maka Nchekwa Bio-Sample Nkwa, Ọ bụrụ na ị nwere mmasị na ngwaahịa ọ bụla, biko nweere onwe gị ịkpọtụrụ anyị maka ozi ndị ọzọ ma ọ bụ zitere anyị email ozugbo, anyị ga-aza gị n'ime awa 24 na a ga-enye nkọwa kacha mma.
Haier Gold Supplier maka China Liquid Nitrogen Tank na Liquid Nitrogen Container, Ụlọ ọrụ anyị na-ekpuchi mpaghara nke 12,000 square mita, ma nwee ndị ọrụ 200 mmadụ, n'etiti nke e nwere ndị isi ọrụ nkà na ụzụ 5.Anyị na-pụrụ iche na-emepụta. Anyị ugbu a nwere ọgaranya ahụmahụ na mbupụ.Nnọọ ịkpọtụrụ anyị na a ga-aza ajụjụ gị ozugbo enwere ike.
Nlereanya | YDS-10-125-F | YDS-30-125-F | YDS-35-125-F | YDS-47-127-6Y | YDS-50B-125-F |
Arụmọrụ | |||||
Ike LN2 (L) | 10 | 31.5 | 35.5 | 47 | 50 |
Ibu efu (kg) | 6.3 | 13 | 14.6 | 18.2 | 17.3 |
Mmepe olu (mm) | 125 | 125 | 125 | 127 | 125 |
Dayameta elu (mm) | 300 | 462 | 462 | 508 | 462 |
N'ozuzu Elu (mm) | 625 | 704 | 748 | 718 | 818 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.42 | 0.35 | 0.36 | 0.36 | 0.45 |
Oge Njide Static (ụbọchị) | 24 | 90 | 97 | 130 | 110 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 1 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 82×84 | 82×84 | 82×84 | 105×100 | 82×84 | |
Akụkụ Vial igbe (mm) | 76×76 | 76×76 | 76×76 | 98 | 76×76 | |
Igbe kwa Rack (ea) | 4 | 4 | 5 | 5 | 6 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 100 | 600/700 | 750/875 | 1110/1295 | 900/1050 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | ── | ── | ── | ── | ── |
Akụkụ ihe mgbochi (mm) | ── | ── | ── | ── | ── | |
Akụkụ Vial igbe (mm) | ── | ── | ── | ── | ── | |
Igbe kwa Rack (ea) | ── | ── | ── | ── | ── | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | ── | ── | ── | ── | ── |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | √ | √ | ── | √ |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | ── | √ | √ | √ | √ |
Nlereanya | YDS-65-216-F | YDS-95-216-F | YDS-115-216-F | YDS-145-216-F | YDS-175-216-F |
Arụmọrụ | |||||
Ike LN2 (L) | 65 | 95 | 115 | 145 | 175 |
Ibu efu (kg) | 38.3 | 41.3 | 42.3 | 48.9 | 53.8 |
Mmepe olu (mm) | 216 | 216 | 216 | 216 | 216 |
Dayameta elu (mm) | 681 | 681 | 681 | 681 | 681 |
N'ozuzu Elu (mm) | 712 | 774 | 846 | 946 | 1060 |
Ọnụego mkpofu ahụ kwụ ọtọ (L/ụbọchị) | 0.78 | 0.97 | 0.94 | 0.96 | 0.95 |
Oge Njide Static (ụbọchị) | 83 | 98 | 122 | 151 | 184 |
Oke nchekwa ike
Racks 2 ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142×144 | 142×144 | 142 x 144 | 142x144 | 142x144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134 x 134 | 134 x 134 | 134 x 134 | 134×134 | |
Igbe kwa Rack (ea) | 4 | 5 | 6 | 8 | 10 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 2400/2800 | 3000/3500 | 3600/4200 | 4800/5600 | 6000/7000 | |
Racks 5ml tube na-ekpo ọkụ | Ọnụọgụ nke Racks (ea) | 6/7 | 6/7 | 6/7 | 6/7 | 6/7 |
Akụkụ ihe mgbochi (mm) | 142x144 | 142x144 | 142 x 144 | 142x144 | 142×144 | |
Akụkụ Vial igbe (mm) | 134 x 134 | 134×134 | 134 x 134 | 134 x 134 | 134 x 134 | |
Igbe kwa Rack (ea) | 2 | 2 | 3 | 4 | 5 | |
1.2;1.8 & 2 ml Vials (nke dị n'ime) | 972/1134 | 972/1134 | 1458/1701 | 1944/2268 | 2430/2835 |
Ngwa ngwa nhọrọ
Ihe mkpuchi nwere ike ịkpọchi | √ | √ | √ | √ | √ |
Akpa PU | ── | ── | ── | ── | ── |
SmartCap | √ | √ | √ | √ | √ |
Roller Base | √ | √ | √ | √ | √ |